Search icon

M&J CONSTRUCTION LLC

Company Details

Name: M&J CONSTRUCTION LLC
Jurisdiction: Colorado
Legal type: Domestic limited liability company
Status: Delinquent
Date of registration: 22 May 2023 (2 years ago)
Entity Number: 20231538546
ZIP code: 80103
County: Adams County
Place of Formation: COLORADO
Principal Address: 2020 Bradbury Krebs Rd Byers CO 80103 US

Agent

Name Role Address
EDUARDO L HERNANDEZ GARCIA Agent 2020 Bradbury Krebs Rd Byers CO 80103 US

Transaction History

Transaction ID Type Date Effective date Name Comment
20231538546 Form a Limited Liability Company (LLC) 2023-05-22 2023-05-22 M&J CONSTRUCTION LLC No data

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344286885 0830500 2019-09-05 10219 YAMPA ST, COMMERCE CITY, CO, 80022
Inspection Type FollowUp
Scope NoInspection
Safety/Health Safety
Close Conference 2019-09-05
Emphasis L: FALL
Case Closed 2019-09-06

Related Activity

Type Inspection
Activity Nr 1416835
Safety Yes
344168356 0830500 2019-07-20 10219 YAMPA, COMMERCE CITY, CO, 80022
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2019-07-20
Emphasis L: FALL, P: FALL
Case Closed 2023-03-31

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2019-08-05
Abatement Due Date 2019-08-29
Current Penalty 3978.0
Initial Penalty 3978.0
Final Order 2019-09-12
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) M&J Construction, LLC at 10219 Yampa Commerce City, CO 80022: On or before 7/20/19 the employer did not protect employees from injury in that employees disassembling a pump jack scaffold on the roof of a two story single family home were not wearing fall protection. This condition exposed employees to a fall hazard of fifteen feet.
344168802 0830500 2019-07-20 17988 106TH PL., COMMERCE CITY, CO, 80022
Inspection Type FollowUp
Scope NoInspection
Safety/Health Safety
Close Conference 2019-07-20
Emphasis L: FALL
Case Closed 2019-07-22

Related Activity

Type Inspection
Activity Nr 1406742
Safety Yes
344067426 0830500 2019-06-08 17988 106TH PL., COMMERCE CITY, CO, 80022
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2019-06-08
Emphasis L: FALL, P: FALL
Case Closed 2023-03-31

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2019-06-19
Abatement Due Date 2019-07-16
Current Penalty 3789.0
Initial Penalty 3789.0
Final Order 2019-08-01
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) M&J Construction, LLC at 17988 106th Pl. Commerce City, CO 80022: On or before 6/8/19 the employer did not protect employees from injury in that an employee working on a patio which was not equipped with guard rails was not wearing fall protection. This condition exposed the employee to a fall hazard of 10 feet.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B13
Issuance Date 2019-06-19
Abatement Due Date 2019-07-16
Current Penalty 2273.0
Initial Penalty 2273.0
Final Order 2019-08-01
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: (a) M&J Construction, LLC at 17988 106th Pl. Commerce City, CO 80022: On or before 6/8/19 the employer did not protect employees from injury in that an employee working on a patio was using a step ladder improperly. The step ladder was folded and leaning against the building. This condition exposed the employee to fall hazards.
343901922 0830600 2019-04-02 57 S OAKHILL COURT, AURORA, CO, 80018
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2019-04-02
Emphasis L: FALL
Case Closed 2022-11-16

Related Activity

Type Complaint
Activity Nr 1441541
Safety Yes
Type Inspection
Activity Nr 1393446
Safety Yes
Type Inspection
Activity Nr 1390215
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 G04 I
Issuance Date 2019-04-19
Abatement Due Date 2019-05-01
Current Penalty 2842.0
Initial Penalty 2842.0
Final Order 2019-05-20
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms: 1) On April 2, 2019, an employee was exposed to fall hazards in excess of 15 while working from a pump jack scaffold that did not have a guardrail system installed on the end of the platform.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2019-04-19
Abatement Due Date 2019-05-01
Current Penalty 2842.0
Initial Penalty 2842.0
Final Order 2019-05-20
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: 1) On April, 2, 2019, an employee working from a pump jack scaffold was exposed to fall hazards in excess of 15 while working from a pump jack scaffold that had poles which did not bear on mud sills or other adequate firm foundation.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260451 C02 I
Issuance Date 2019-04-19
Abatement Due Date 2019-05-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-05-20
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement: 1) On April, 2, 2019, an employee was exposed to fall hazards in excess of 15 while working from a pump jack scaffold that had footings which were not level.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2019-04-19
Abatement Due Date 2019-05-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-05-20
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: 1) On or about April, 2, 2019, a pump jack scaffold was not erected under the supervision and direction of a competent person.
Citation ID 01002D
Citaton Type Serious
Standard Cited 19260452 J02
Issuance Date 2019-04-19
Abatement Due Date 2019-05-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-05-20
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary: 1) On April, 2, 2019, an employee was exposed to fall hazards in excess of 15 while working from a pump jack scaffold that had poles which were not secured to the structure by triangular bracing at the bottom.

Date of last update: 10 Mar 2025

Sources: Colorado's Secretary of State