Inspection Type |
Unprog Rel
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2021-09-24
|
Emphasis |
L: FALL
|
Related Activity
Type |
Inspection |
Activity Nr |
1554420 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2021-10-19 |
Abatement Due Date |
2021-11-08 |
Current Penalty |
9557.0 |
Initial Penalty |
9557.0 |
Final Order |
2021-11-17 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) Supreme Service LLC at 4189 S Fraser Ct. Aurora, CO 80014: On or before 9/23/21 Supreme Service LLC as the creating and exposing employer did not protect employees from injury in that roofing employees were not wearing fall protection as required by this standard. This condition exposed employees to fall hazards of 8 feet and 10 feet. Abatement Note: Abatement certification and documentation are required for this item. See enclosed "Certification of Corrective Actions Worksheet." |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260503 A01 |
Issuance Date |
2021-10-19 |
Abatement Due Date |
2021-11-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2021-11-17 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: (a) Supreme Service LLC at 4189 S Fraser Ct. Aurora, CO 80014: On or before 9/23/21 Supreme Service LLC as the creating and exposing employer did not protect employees from injury in that roofing employees were not given effective information and training on the fall hazard associated with the work being performed as well as how to effectively use their assigned personal fall arrest systems. Employees were working with their lifelines maxed out. Anchors were connected to multiple lifelines. These conditions exposed employees to fall hazards of 8 feet and 10 feet. Abatement Note: Abatement certification and documentation are required for this item. See enclosed "Certification of Corrective Actions Worksheet." |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260502 D15 |
Issuance Date |
2021-10-19 |
Abatement Due Date |
2021-11-08 |
Current Penalty |
9557.0 |
Initial Penalty |
9557.0 |
Final Order |
2021-11-17 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person: (a) Supreme Service LLC at 4189 S Fraser Ct. Aurora, CO 80014: On or before 9/23/21 Supreme Service LLC as the creating and exposing employer did not protect employees from injury in that roofing employees were using anchors attached to building facia with more than one lifeline attached to it. This condition exposed employees to fall hazards of 8 feet and 10 feet. Abatement Note: Abatement certification and documentation are required for this item. See enclosed "Certification of Corrective Actions Worksheet." |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260502 D16 III |
Issuance Date |
2021-10-19 |
Abatement Due Date |
2021-11-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2021-11-17 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level: (a) Supreme Service LLC at 4189 S Fraser Ct. Aurora, CO 80014: On or before 9/23/21 Supreme Service LLC as the creating and exposing employer did not protect employees from injury in that roofing employees were using fall protection systems with lifelines that were not rigged to limit free fall. An employee working at the edge of the roof with an 8 foot fall hazard had his lifeline fully extended and would not have prevented a fall. Abatement Note: Abatement certification and documentation are required for this item. See enclosed "Certification of Corrective Actions Worksheet." |
|
|