Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-03-19
|
Emphasis |
L: OILGAS, N: AMPUTATE
|
Case Closed |
2015-07-29
|
Related Activity
Type |
Referral |
Activity Nr |
969265 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1075683 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2015-06-26 |
Abatement Due Date |
2015-07-16 |
Current Penalty |
3000.0 |
Initial Penalty |
5000.0 |
Final Order |
2015-07-28 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to caught-in-between hazards: (a)All Around Roustabout, LLC, Noble Energy NCLP-AA04-66-1HN, Briggsdale, CO 80611: On and before March 19th, 2015, the employer did not ensure that an employee involved in removing and replacing two dowel pins that connect the John Deere 624J loader coupler mechanism hydraulic to a pin was protected from caught-in-between hazards. The mechanic was attempting to line up the holes to install a new dowel pin when the loader operator extended the pin and caught the mechanics fingers between the pin fastener end and the hole for the pin. The employee sustained a laceration of the right middle finger and an amputation of approximately 2 inches to the right index finger. This condition exposed an employee to a laceration and amputation hazard. Abatement Note: Among other methods, one feasible and acceptable method to correct this hazard is to develop and implement specific procedural elements to control hazardous energy in accordance with the American National Standards Institute (ANSI)-American Society of Safety Engineers (ASSE) Z244.1-2003 publication. |
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2011-09-26
|
Emphasis |
L: OILGAS
|
Case Closed |
2012-05-24
|
Related Activity
Type |
Complaint |
Activity Nr |
78562 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100023 C01 |
Issuance Date |
2011-12-01 |
Abatement Due Date |
2011-12-16 |
Current Penalty |
2380.0 |
Initial Penalty |
2380.0 |
Final Order |
2012-01-03 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: (a) All Around Roustabout, LLC @ 30985 WCR 64, Gill, CO 80624: On and before 9/26/11, the employer did not ensure that the floor above the parts storage area was guarded by standard railings. Employees accessed the top of the parts storage area to store various parts and vehicle-related materials. This condition exposed employees to an 8 foot fall hazard. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100334 A02 I |
Issuance Date |
2011-12-01 |
Abatement Due Date |
2011-12-16 |
Current Penalty |
1785.0 |
Initial Penalty |
1785.0 |
Final Order |
2012-01-03 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.334(a)(2)(i): The employer did not ensure that portable cord- and plug-connected equipment and flexible cord sets (extension cords) were visually inspected before use on any shift for external defects and for evidence of possible internal damage: (a) All Around Roustabout, LLC @ 30985 WCR 64, Gill, CO 80624: On and before 9/26/11, the employer did not inspect the extension cords that were used to power outdoor diesel and gasoline fuel pumps. Employees access the fuel pumps daily. The outer jacket on the extension cords were damaged thereby exposing the inner conductors. The jacket for the inner conductors, however, was not damaged. This condition exposed employees to shock hazards. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100334 A02 II |
Issuance Date |
2011-12-01 |
Abatement Due Date |
2011-12-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-01-03 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.334(a)(2)(ii): The employer did not ensure that damaged flexible cord sets that might injure an employee were removed from service: (a) All Around Roustabout, LLC @ 30985 WCR 64, Gill, CO 80624: On and before 9/26/11, the employer did not remove from service the extension cords that were used to power outdoor diesel and gasoline fuel pumps. Employees access the fuel pumps daily. The outer jacket on the extension cords were damaged thereby exposing the inner conductors. The jacket for the inner conductors, however, was not damaged. This condition exposed employees to shock hazards. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100022 D01 |
Issuance Date |
2011-12-01 |
Abatement Due Date |
2011-12-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-01-03 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed to the building: (a) All Around Roustabout, LLC @ 30985 WCR 64, Gill, CO 80624: On and before 9/26/11, the employer did not ensure that parts cage was equipped with a load rating. Employees stored various parts and materials on top of the parts cage. (b) All Around Roustabout, LLC @ 30985 WCR 64, Gill, CO 80624: On and before 9/26/11, the employer did not ensure that a storage system was equipped with a load rating. The employer purchased a storage system where 4, 275 gallon totes containing various vehicle-related fluids were located. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19101200 F05 II |
Issuance Date |
2011-12-01 |
Abatement Due Date |
2011-12-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-01-03 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings: (a) All Around Roustabout, LLC @ 30985 WCR 64, Gill, CO 80624: On and before 9/26/11, the employer did not ensure that containers were properly marked with its contents. The employer purchased 5-gallon water containers are used, after exhausted, for storing other liquids such as, but not including, antifreeze and non-potable water. |
|
|