Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2014-12-03
|
Emphasis |
L: SILICA, N: SILICA
|
Case Closed |
2019-07-09
|
Related Activity
Type |
Referral |
Activity Nr |
911238 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100242 B |
Issuance Date |
2014-12-08 |
Abatement Due Date |
2015-01-05 |
Current Penalty |
1200.0 |
Initial Penalty |
1200.0 |
Final Order |
2015-01-08 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: 1) On October 1, 2014, Master Stone, LLC, as the creating employer, did not ensure that employees of JP Marble & Granite were protected from injuries when using compressed air to blow dust off their clothing that was not reduced to less than 30 p.s.i. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100334 A02 II |
Issuance Date |
2014-12-08 |
Abatement Due Date |
2015-01-05 |
Current Penalty |
2400.0 |
Initial Penalty |
2400.0 |
Final Order |
2015-01-08 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service until repairs and tests necessary to render the equipment safe were made: 1) On October 15, 2014, Master Stone, LLC, as the creating employer, did not ensure that employees of JP Marble & Granite were protected from injuries while operating a granite saw that had strain relief pulled loose at the plug end of the cord. |
|
|