Search icon

ARCHIBEQUE ROOFING INC.

Company Details

Name: ARCHIBEQUE ROOFING INC.
Jurisdiction: Colorado
Legal type: Domestic profit corporation
Status: Delinquent
Date of registration: 13 May 2004 (21 years ago)
Date dissolved: 01 Aug 2013
Entity Number: 20041176402
ZIP code: 80110
County: Arapahoe County
Place of Formation: COLORADO
Principal Address: 2749 W FLOYD AVE SHERIDAN CO 80110 US

Agent

Name Role Address
RUDY ARCHIBEQUE Agent 2749 W FLOYD AVE SHERIDAN CO 80110 US

Transaction History

Transaction ID Type Date Effective date Name Comment
20121186807 Statement Curing Delinquency 2012-03-28 2012-03-28 ARCHIBEQUE ROOFING INC. No data
20061393954 Statement Curing Delinquency 2006-09-27 2006-09-27 ARCHIBEQUE ROOFING INC. No data
20041176402 Articles of Incorporation 2004-05-13 2004-05-13 ARCHIBEQUE ROOFING INC. ARCHIBEQUE ROOFING INC.

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
330924275 0830600 2011-07-15 6270 W. 55TH AVE., ARVADA, CO, 80002
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2011-07-15
Emphasis L: FALL
Case Closed 2017-01-09

Related Activity

Type Complaint
Activity Nr 74964
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260502 F01
Issuance Date 2011-08-11
Abatement Due Date 2011-08-16
Current Penalty 1530.0
Initial Penalty 1530.0
Final Order 2011-09-21
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(f)(1): Warning lines were not erected around all sides of the roof work area: a) On or about July 15, 2011, employees were not protected from fall hazards in excess of 6 feet in that, the warning line system in use at the site was not erected around all sides of the roof work area. The warning line was only partially erected. Abatement Note: Abatement certification is required for this item. See enclosed Sample Abatement Certification Letter.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260502 F02
Issuance Date 2011-08-11
Abatement Due Date 2011-08-16
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2011-09-21
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(f)(2): Warning line systems did not consist of ropes, wires, or chains, and supporting stanchions erected in accordance with (f)(2)(i) through (f)(2)(v) of this section: a) On or about July 15, 2011, the partial warning line at the site contain the following deficiencies: 1. Plastic caution tape was used which was not of sufficient strength (500 lb tensile strength minimum requirement). 2. The line was not flagged at 6 foot intervals with high visibility material. 3. The line was sagging in areas along the front of the roof to less than 34 inches. Abatement Note: Abatement certification is required for this item. See enclosed Sample Abatement Certification Letter.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2011-08-11
Abatement Due Date 2011-08-16
Current Penalty 2040.0
Initial Penalty 2040.0
Final Order 2011-09-21
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) On or about July 15, 2011, employees were exposed to fall hazards while using a ladder to access a roof where the ladder did not extend at least 3 feet above the roof surface. Abatement Note: Abatement certification is required for this item. See enclosed Sample Abatement Certification Letter.
307524017 0830500 2004-08-08 6301 W. HAMPDEN AVE., PEACHTREE 2 APTS., DENVER, CO, 80227
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2004-08-08
Emphasis L: FALL
Case Closed 2005-05-19

Related Activity

Type Complaint
Activity Nr 204469142
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19260501 B13
Issuance Date 2004-08-11
Abatement Due Date 2004-09-13
Current Penalty 375.0
Initial Penalty 375.0
Nr Instances 2
Nr Exposed 6
Related Event Code (REC) Complaint
Gravity 03
Citation ID 01002
Citaton Type Other
Standard Cited 19261053 B01
Issuance Date 2004-08-11
Abatement Due Date 2004-09-13
Current Penalty 375.0
Initial Penalty 375.0
Nr Instances 1
Nr Exposed 6
Related Event Code (REC) Complaint
Gravity 03
307523902 0830500 2004-08-06 6301 W. HAMPDEN AVE., PEACHTREE 2 APTS., DENVER, CO, 80227
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2004-08-06
Emphasis L: FALL
Case Closed 2004-08-10
106418585 0830500 1993-09-28 10050 EAST HARVARD, DENVER, CO, 80231
Inspection Type Complaint
Scope Complete
Safety/Health Safety
Close Conference 1993-09-28
Case Closed 1994-01-28

Related Activity

Type Complaint
Activity Nr 73717126
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260059 E01
Issuance Date 1993-10-08
Abatement Due Date 1993-11-08
Current Penalty 225.0
Initial Penalty 225.0
Nr Instances 1
Nr Exposed 8
Gravity 01
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260059 G01
Issuance Date 1993-10-08
Abatement Due Date 1993-11-08
Nr Instances 1
Nr Exposed 8
Gravity 01
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260059 H
Issuance Date 1993-10-08
Abatement Due Date 1993-11-08
Nr Instances 1
Nr Exposed 8
Gravity 01

Date of last update: 24 Feb 2025