Name: | THOMPSON & SITZ CONSTRUCTION, INC. |
Jurisdiction: | Colorado |
Legal type: | Domestic profit corporation |
Status: | Good Standing |
Date of registration: | 06 May 1999 (26 years ago) |
Entity Number: | 19991086323 |
ZIP code: | 80116 |
County: | Douglas County |
Place of Formation: | COLORADO |
Principal Address: | 10691 Pronghorn Pl Franktown CO 80116 US |
Plan Name | Plan Year | EIN/PN | Received | Sponsor | Total number of participants | |||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
THOMPSON & SITZ CONSTRUCTION 401K PROFIT SHARING PLAN | 2023 | 841503835 | 2024-07-01 | THOMPSON & SITZ CONSTRUCTION | 18 | |||||||||||||||||||||||
|
Role | Plan administrator |
Date | 2024-07-01 |
Name of individual signing | TODD URBACH |
Valid signature | Filed with authorized/valid electronic signature |
File | View Page |
Three-digit plan number (PN) | 001 |
Effective date of plan | 2004-01-01 |
Business code | 238100 |
Sponsor’s telephone number | 7207337519 |
Plan sponsor’s address | 10691 PRONGHORN PL, FRANKTOWN, CO, 80116 |
Signature of
Role | Plan administrator |
Date | 2023-07-24 |
Name of individual signing | TODD URBACH |
Valid signature | Filed with authorized/valid electronic signature |
File | View Page |
Three-digit plan number (PN) | 001 |
Effective date of plan | 2004-01-01 |
Business code | 238100 |
Sponsor’s telephone number | 7207337519 |
Plan sponsor’s address | 10691 PRONGHORN PL, FRANKTOWN, CO, 80116 |
Signature of
Role | Plan administrator |
Date | 2022-05-18 |
Name of individual signing | TODD URBACH |
Valid signature | Filed with authorized/valid electronic signature |
File | View Page |
Three-digit plan number (PN) | 001 |
Effective date of plan | 2004-01-01 |
Business code | 238100 |
Sponsor’s telephone number | 7207337519 |
Plan sponsor’s address | 10691 PRONGHORN PL, FRANKTOWN, CO, 80116 |
Signature of
Role | Plan administrator |
Date | 2021-07-22 |
Name of individual signing | TODD URBACH |
Valid signature | Filed with authorized/valid electronic signature |
File | View Page |
Three-digit plan number (PN) | 001 |
Effective date of plan | 2004-01-01 |
Business code | 238100 |
Sponsor’s telephone number | 7207337519 |
Plan sponsor’s address | 10691 PRONGHORN PL, FRANKTOWN, CO, 80116 |
Signature of
Role | Plan administrator |
Date | 2020-07-16 |
Name of individual signing | TODD URBACH |
Valid signature | Filed with authorized/valid electronic signature |
File | View Page |
Three-digit plan number (PN) | 001 |
Effective date of plan | 2004-01-01 |
Business code | 238100 |
Sponsor’s telephone number | 7207337519 |
Plan sponsor’s address | 10691 PRONGHORN PL, FRANKTOWN, CO, 80116 |
Signature of
Role | Plan administrator |
Date | 2019-06-21 |
Name of individual signing | TODD URBACH |
Valid signature | Filed with authorized/valid electronic signature |
File | View Page |
Three-digit plan number (PN) | 001 |
Effective date of plan | 2004-01-01 |
Business code | 238100 |
Sponsor’s telephone number | 7207337519 |
Plan sponsor’s address | 10691 PRONGHORN PL, FRANKTOWN, CO, 80116 |
Signature of
Role | Plan administrator |
Date | 2018-07-16 |
Name of individual signing | TODD URBACH |
Valid signature | Filed with authorized/valid electronic signature |
File | View Page |
Three-digit plan number (PN) | 001 |
Effective date of plan | 2004-01-01 |
Business code | 238100 |
Sponsor’s telephone number | 7207337519 |
Plan sponsor’s address | 10691 PRONGHORN PL, FRANKTOWN, CO, 80116 |
Signature of
Role | Plan administrator |
Date | 2017-07-24 |
Name of individual signing | TODD URBACH |
Valid signature | Filed with authorized/valid electronic signature |
File | View Page |
Three-digit plan number (PN) | 001 |
Effective date of plan | 2004-01-01 |
Business code | 238100 |
Sponsor’s telephone number | 7207337519 |
Plan sponsor’s address | 10691 PRONGHORN PL, FRANKTOWN, CO, 80116 |
Signature of
Role | Plan administrator |
Date | 2016-07-07 |
Name of individual signing | TODD URBACH |
Valid signature | Filed with authorized/valid electronic signature |
Name | Role | Address |
---|---|---|
MIKE SITZ | Agent | 10691 Pronghorn Pl Franktown CO 80116 US |
Transaction ID | Type | Date | Effective date | Name | Comment |
---|---|---|---|---|---|
20241451302 | File Report | 2024-04-23 | 2024-04-23 | No data | Principal address changed, Change in registered agent information |
20231440088 | File Report | 2023-04-25 | 2023-04-25 | No data | Principal address changed, Change in registered agent information |
20221412425 | File Report | 2022-04-25 | 2022-04-25 | No data | No data |
20211383293 | File Report | 2021-04-23 | 2021-04-23 | No data | Removed agent mailing address; |
20201364146 | File Report | 2020-04-24 | 2020-04-24 | No data | No data |
20191339036 | File Report | 2019-04-23 | 2019-04-23 | No data | No data |
20181323956 | File Report | 2018-04-23 | 2018-04-23 | No data | No data |
20171333066 | File Report | 2017-04-28 | 2017-04-28 | No data | No data |
20161515981 | File Report | 2016-07-29 | 2016-07-29 | No data | No data |
20151476767 | File Report | 2015-07-24 | 2015-07-24 | No data | No data |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
343370011 | 0830500 | 2018-08-08 | 2880 CURTIS ST, DENVER, CO, 80205 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1339955 |
Safety | Yes |
Type | Referral |
Activity Nr | 1368311 |
Safety | Yes |
Inspection Type | Prog Related |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2018-07-14 |
Emphasis | P: FALL, L: FALL |
Case Closed | 2018-08-03 |
Related Activity
Type | Inspection |
Activity Nr | 1332705 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1330022 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1333522 |
Safety | Yes |
Inspection Type | Complaint |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2017-07-19 |
Emphasis | L: FALL, P: FALL |
Case Closed | 2017-09-27 |
Related Activity
Type | Inspection |
Activity Nr | 1256029 |
Safety | Yes |
Type | Complaint |
Activity Nr | 1241878 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260025 A |
Issuance Date | 2017-08-25 |
Abatement Due Date | 2017-09-05 |
Current Penalty | 2661.0 |
Initial Penalty | 3802.0 |
Final Order | 2017-09-20 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.25(a): During the course of construction, alteration, or repairs, form or scrap lumber with protruding nails was not kept clear from work areas: (a) On or about July 19, 2017, and at times prior, employees were exposed to lacerations, impalement hazards, slips, trips and falls due to inadequate housekeeping, including, but not limited to protruding nails from scrap lumber throughout the third floor of building 13. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet"). |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2017-08-25 |
Abatement Due Date | 2017-08-31 |
Current Penalty | 6200.0 |
Initial Penalty | 8873.0 |
Final Order | 2017-09-20 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) On or about July 19, 2017, Thompson & Sitz Construction, Inc., as the controlling employer, did not ensure that A Villa Carpenters, Inc. (subcontractor) protected their employees from fall hazards of 30 feet and greater while engaged in residential construction activities. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet"). |
Citation ID | 01003A |
Citaton Type | Serious |
Standard Cited | 19260502 B02 I |
Issuance Date | 2017-08-25 |
Current Penalty | 4436.0 |
Initial Penalty | 6338.0 |
Final Order | 2017-09-20 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.502(b)(2): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structure members were not installed between the top edge of the guardrail system and the walking/working surface when there was no wall or parapet wall at least 21 inches (53 cm) high. (a) On or about July 19, 2017, and at times prior, employees were exposed to fall hazards in excess of six feet in that a mid-rail was not installed along the guardrail that was installed adjacent to the open sided floor. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet"). |
Citation ID | 01003B |
Citaton Type | Serious |
Standard Cited | 19261052 C12 |
Issuance Date | 2017-08-25 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2017-09-20 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems that meet the criteria contained in Subpart M of 29 CFR 1926: (a) On or about July 19, 2017, and at times prior, employees were exposed to fall hazards in excess of six feet in the stairway landing in between the second and third floor where the guardrail was missing a mid-rail. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet"). |
Inspection Type | Unprog Rel |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2017-07-17 |
Emphasis | L: FALL |
Case Closed | 2017-08-16 |
Related Activity
Type | Inspection |
Activity Nr | 1229848 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1231702 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1231736 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1229845 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260502 B04 |
Issuance Date | 2017-07-19 |
Abatement Due Date | 2017-08-14 |
Current Penalty | 1800.0 |
Initial Penalty | 2716.0 |
Final Order | 2017-08-03 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.502(b)(4): When the 200 pound (890 N) test load specified in paragraph (b)(3) of this section was applied in a downward direction, the top edge of the guardrail deflected to a height less than 39 inches (1.0 m) above the walking/working level: 1) On May 1, 2017, and at prior times, Thompson & Sitz Construction, Inc., as the controlling employer, did not ensure that employees were protected from falls when working near the top rail of a guardrail system that deflected to a height of less than 39 inches above the walking/working level. |
Inspection Type | Prog Related |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2002-05-23 |
Emphasis | L: FALL, S: CONSTRUCTION |
Case Closed | 2002-06-18 |
Inspection Type | Unprog Rel |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2002-02-08 |
Case Closed | 2002-03-12 |
Related Activity
Type | Referral |
Activity Nr | 201755196 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2002-02-11 |
Abatement Due Date | 2002-02-22 |
Current Penalty | 300.0 |
Initial Penalty | 750.0 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 03 |