Search icon

RESIDENT MANAGEMENT SYSTEMS, INC.

Company Details

Name: RESIDENT MANAGEMENT SYSTEMS, INC.
Jurisdiction: Colorado
Legal type: Domestic profit corporation
Status: Good Standing
Date of registration: 15 Nov 1996 (28 years ago)
Entity Number: 19961149366
ZIP code: 80906
County: El Paso County
Place of Formation: COLORADO
Principal Address: 1390 Quail Lake Loop Colorado Springs CO 80906 US

Transaction History

Transaction ID Type Date Effective date Name Comment
20248142486 File Report 2024-10-24 2024-10-24 No data Principal address changed, Change in registered agent information
20241727486 Statement of Change Changing the Registered Agent Information 2024-07-09 2024-07-09 No data Registered agent information changed;
20231836378 File Report 2023-08-11 2023-08-11 No data Principal address changed, Change in registered agent information
20228033963 File Report 2022-10-24 2022-10-24 No data Change in registered agent information
20211664229 File Report 2021-07-23 2021-07-23 No data No data
20201630468 File Report 2020-07-23 2020-07-23 No data No data
20191853583 File Report 2019-10-24 2019-10-24 No data No data
20181612448 File Report 2018-08-01 2018-08-01 No data Change of Registered Agent Address
20181217103 Statement of Change Changing the Registered Agent Information 2018-03-15 2018-03-15 No data Registered agent information changed;Removed agent mailing address;
20171811252 File Report 2017-10-27 2017-10-27 No data No data

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339746554 0830600 2014-04-23 220 N. MURRAY BLVD., COLORADO SPRINGS, CO, 80916
Inspection Type Referral
Scope Partial
Safety/Health Health
Close Conference 2014-04-23
Emphasis L: ASBESTOS, P: ASBESTOS
Case Closed 2016-06-01

Related Activity

Type Referral
Activity Nr 882535
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19261101 F02 I
Issuance Date 2014-06-12
Abatement Due Date 2014-07-30
Current Penalty 2310.0
Initial Penalty 2310.0
Final Order 2014-07-15
Nr Instances 1
Nr Exposed 6
Related Event Code (REC) Referral
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1101(f)(2)(i): The employer with a work operation covered by the asbestos standard did not ensure that a "competent person" conducted an exposure assessment immediately before or at the initiation of the operation to ascertain expected exposures during that operation: a) On or about April 23, 2014, and at times prior, employees were exposed to unknown quantities of airborne asbestos fibers while conducting maintenance and housekeeping activities that disturbed asbestos containing materials (ACM) or presumed asbestos containing materials (PACM) such as drywall and ceiling texturing because the employer failed to perform an initial exposure assessment at or before the commencement of these activities.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19261101 G09
Issuance Date 2014-06-12
Abatement Due Date 2014-07-30
Current Penalty 2310.0
Initial Penalty 2310.0
Final Order 2014-07-15
Nr Instances 1
Nr Exposed 6
Related Event Code (REC) Referral
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1101(g)(9): The employer did not follow the work practices and engineering controls for Class III asbestos work specified in 29 CFR 1926.1101(g)(9)(i) through (g)(9)(v), to minimize the exposure to employees: a) On or about April 23, 2014, and at times prior, employees were exposed to unknown quantities of airborne asbestos fibers while conducting maintenance and housekeeping activities that disturbed asbestos containing materials (ACM) or presumed asbestos containing materials (PACM) such as drywall and ceiling texturing because the employer did not ensure that controls such as isolation/enclosures, ventilation, and wet methods were utilized.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19261101 H03 III
Issuance Date 2014-06-12
Abatement Due Date 2014-07-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-07-15
Nr Instances 1
Nr Exposed 6
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1101(h)(3)(iii): The employer did not provide employees with an air-purifying half mask respirator, other than a filtering facepiece respirator, whenever the employees performed Class III asbestos work for which no negative exposure assessment was available or Class III asbestos work involving disturbance of TSI or surfacing ACM or PACM: a) On or about April 23, 2014, and at times prior, employees were exposed to unknown quantities of airborne asbestos fibers while conducting maintenance and housekeeping activities that disturbed asbestos containing materials (ACM) or presumed asbestos containing materials (PACM) such as drywall and ceiling texturing because the employer failed to provide them with an adequate respirator.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19261101 K09 I
Issuance Date 2014-06-12
Abatement Due Date 2014-07-30
Current Penalty 2310.0
Initial Penalty 2310.0
Final Order 2014-07-15
Nr Instances 1
Nr Exposed 6
Related Event Code (REC) Referral
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1101(k)(9)(i): The employer did not institute a training program for all employees who are likely to be exposed in excess of a PEL and for all employees who perform Class I through Class IV asbestos operations, and did not ensure their participation in the program: a) On or about April 23, 2014, and at times prior, employees were exposed to asbestos because they were not provided with adequate training for Class III and Class IV asbestos operations. Several employees regularly conducted Class III asbestos activities, cutting through asbestos containing materials (ACM) or potentially asbestos containing materials (PACM) such as surfacing materials for drywall and ceilings in order to perform maintenance work. In addition, both maintenance and housekeeping staff conducted Class IV asbestos activities on a daily basis.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19261101 K02 I
Issuance Date 2014-06-12
Abatement Due Date 2014-07-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-07-15
Nr Instances 1
Nr Exposed 6
Related Event Code (REC) Referral
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1101(k)(2)(i): Before work subject to this standard was begun, building and facility owners did not determine the presence, location, and quantity of ACM and/or PACM at the work site pursuant to paragraph (k)(1) of this section: a) On or about April 23, 2014, and at times prior, employees were exposed to asbestos fibers because the employer failed to determine the presence, location and quantity of asbestos in wall and ceiling texturing that was occasionally disturbed by maintenance and housekeeping employees and failed to provide such information to the employees working in the building.
334166824 0830600 2012-05-02 260 N. MURRY BLVD., COLORADO SPRINGS, CO, 80916
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2012-05-02
Case Closed 2013-01-23

Related Activity

Type Complaint
Activity Nr 331620
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260453 B02 V
Issuance Date 2012-05-22
Abatement Due Date 2012-05-25
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2012-06-20
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift: a) On or about May 2, 2012 and at times prior, employees were not protected from falls while operating a JLG aerial lift in that, fall restraint systems were not used by employees to prevent them from falling out of the basket of the lift.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260453 B02 VII
Issuance Date 2012-05-22
Abatement Due Date 2012-05-25
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-06-20
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.453(b)(2)(vii): Wheel chocks were not installed before using an aerial lift on an incline, provided they can be safely installed: a) On or about May 2, 2012, employees used an aeria llift on an un-even and inclided surface and did not use wheel chocks to prevent the lift from rolling down the incline.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260454 B
Issuance Date 2012-05-22
Abatement Due Date 2012-05-25
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-06-20
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(b): The employer did not have each employee involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question: a) On or about May 2, 2012 and at times prior, employees were not trained on the proper and safe operation of a JLG aerial lift at the site prior to use.
312135197 0830600 2008-08-12 1390 QUAIL LAKE LOOP, COLORADO SPRINGS, CO, 80906
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2008-08-12
Case Closed 2008-09-22

Related Activity

Type Complaint
Activity Nr 206711376
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Other
Standard Cited 19100215 A04
Issuance Date 2008-09-12
Abatement Due Date 2008-09-26
Current Penalty 525.0
Initial Penalty 525.0
Nr Instances 1
Nr Exposed 1
Gravity 01
Citation ID 01001B
Citaton Type Other
Standard Cited 19100215 B09
Issuance Date 2008-09-12
Abatement Due Date 2008-09-26
Nr Instances 1
Nr Exposed 1
Gravity 01
Citation ID 01002A
Citaton Type Other
Standard Cited 19100303 G02 I
Issuance Date 2008-09-12
Abatement Due Date 2008-09-26
Current Penalty 2500.0
Initial Penalty 2500.0
Nr Instances 1
Nr Exposed 1
Gravity 10
Citation ID 01002B
Citaton Type Other
Standard Cited 19100305 B02
Issuance Date 2008-09-12
Abatement Due Date 2008-09-26
Nr Instances 1
Nr Exposed 1
Gravity 03

Date of last update: 10 Mar 2025

Sources: Colorado's Secretary of State