343682860
|
0830600
|
2018-12-20
|
1825 W. CASPIAN PL UNIT 2A, ENGLEWOOD, CO, 80110
|
|
Inspection Type |
FollowUp
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2018-12-20
|
Case Closed |
2024-03-22
|
Related Activity
Type |
Inspection |
Activity Nr |
1300338 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19101200 G08 |
Issuance Date |
2019-05-10 |
Abatement Due Date |
2019-06-06 |
Current Penalty |
1705.0 |
Initial Penalty |
1705.0 |
Final Order |
2019-06-05 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(g)(8): The employer did not ensure that safety data sheets were readily accessible to the employees in their work area during each work shift: a) On or about December 20, 2018, and at times prior, the employer, Hartson Enterprises, Inc., did not ensure safety data sheets for the sprayed adhesive Formica 575 was kept readily accessible to employees in the facility. |
|
Citation ID |
02001A |
Citaton Type |
Repeat |
Standard Cited |
19100213 C02 |
Issuance Date |
2019-05-10 |
Current Penalty |
4546.0 |
Initial Penalty |
4546.0 |
Final Order |
2019-06-05 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator: a) On or about December 20, 2018, and at times prior, the employer, Hartson Enterprises, Inc., did not ensure employees were protected from stuck-by hazards while operating and working in the vicinity of a SCMI table saw without a spreader device. HARTSON ENTERPRISES INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF OCCUPATIONAL SAFETY AND HEALTH STANDARD 29 CFR 1910.213(c)(2) OR ITS EQUIVALENT WHICH WAS CONTAINED IN OSHA INSPECTION 1300338, CITATION 1, ITEM 1b, WHICH WAS AFFIRMED AS A FINAL ORDER ON MAY 8, 2018, WITH RESPECT TO THE WORKPLACE LOCATED AT 1825 W. CASPIAN PL., ENGLEWOOD, COLORADO 80110. HARTSON ENTERPRISES INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF OCCUPATIONAL SAFETY AND HEALTH STANDARD 29 CFR 1910.213(c)(2) OR ITS EQUIVALENT WHICH WAS CONTAINED IN OSHA INSPECTION 1008783, CITATION 1, ITEM 1a, WHICH WAS AFFIRMED AS A FINAL ORDER ON MAY 27, 2015, WITH RESPECT TO THE WORKPLACE LOCATED AT 3340 S. ZUNI STREET, BUILDING A, ENGLEWOOD, COLORADO 80110. HARTSON ENTERPRISES INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF OCCUPATIONAL SAFETY AND HEALTH STANDARD 29 CFR 1910.213(c)(2) OR ITS EQUIVALENT WHICH WAS CONTAINED IN OSHA INSPECTION 981784, CITATION 1, ITEM 1a, WHICH WAS AFFIRMED AS A FINAL ORDER ON OCTOBER 8, 2014, WITH RESPECT TO THE WORKPLACE LOCATED AT 3340 S. ZUNI STREET, BUILDING A, ENGLEWOOD, COLORADO 80110. |
|
Citation ID |
02001B |
Citaton Type |
Repeat |
Standard Cited |
19100213 C03 |
Issuance Date |
2019-05-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-06-05 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: a) On or about December 20, 2018, and at times prior, the employer, Hartson Enterprises, Inc., did not ensure employees were protected from kickback (struck-by) hazards while operating and working in the vicinity of a SCMI table saw which was not equipped with non-kickback fingers. HARTSON ENTERPRISES INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF OCCUPATIONAL SAFETY AND HEALTH STANDARD 29 CFR 1910.213(c)(3) OR ITS EQUIVALENT WHICH WAS CONTAINED IN OSHA INSPECTION 1300338, CITATION 1, ITEM 1c, WHICH WAS AFFIRMED AS A FINAL ORDER ON MAY 8, 2018, WITH RESPECT TO THE WORKPLACE LOCATED AT 1825 W. CASPIAN PL., ENGLEWOOD, COLORADO 80110. HARTSON ENTERPRISES INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF OCCUPATIONAL SAFETY AND HEALTH STANDARD 29 CFR 1910.213(c)(3) OR ITS EQUIVALENT WHICH WAS CONTAINED IN OSHA INSPECTION 1008783, CITATION 1, ITEM 1b, WHICH WAS AFFIRMED AS A FINAL ORDER ON MAY 27, 2015, WITH RESPECT TO THE WORKPLACE LOCATED AT 3340 S. ZUNI STREET, BUILDING A, ENGLEWOOD, COLORADO 80110. HARTSON ENTERPRISES INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF OCCUPATIONAL SAFETY AND HEALTH STANDARD 29 CFR 1910.213(c)(3) OR ITS EQUIVALENT WHICH WAS CONTAINED IN OSHA INSPECTION 981784, CITATION 1, ITEM 1b, WHICH WAS AFFIRMED AS A FINAL ORDER ON OCTOBER 8, 2014, WITH RESPECT TO THE WORKPLACE LOCATED AT 3340 S. ZUNI STREET, BUILDING A, ENGLEWOOD, COLORADO 80110. |
|
Citation ID |
02002 |
Citaton Type |
Repeat |
Standard Cited |
19100036 D01 |
Issuance Date |
2019-05-10 |
Current Penalty |
300.0 |
Initial Penalty |
300.0 |
Final Order |
2019-06-05 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge: a) On or about December 20, 2018, and at times prior, the employer, Hartson Enterprises, Inc., did not ensure the rear exit door was unlocked which would allow employee egress in case of fire or other emergency. HARTSON ENTERPRISES INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF OCCUPATIONAL SAFETY AND HEALTH STANDARD 29 CFR 1910.36(d)(1) OR ITS EQUIVALENT WHICH WAS CONTAINED IN OSHA INSPECTION 1300338, CITATION 2, ITEM 1, WHICH WAS AFFIRMED AS A FINAL ORDER ON MAY 8, 2018, WITH RESPECT TO THE WORKPLACE LOCATED AT 1825 W. CASPIAN PL., ENGLEWOOD, COLORADO 80110. |
|
|
343003380
|
0830600
|
2018-02-22
|
1825 W. CASPIAN PLACE, ENGLEWOOD, CO, 80110
|
|
Inspection Type |
FollowUp
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2018-02-22
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2022-04-28
|
Related Activity
Type |
Inspection |
Activity Nr |
1120351 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Repeat |
Standard Cited |
19100213 C01 |
Issuance Date |
2018-04-09 |
Current Penalty |
4435.0 |
Initial Penalty |
4435.0 |
Final Order |
2018-05-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: a) On or about February 22, 2018, and at times prior, the employer, Hartson Enterprises, Inc., did not ensure employees were protected from blade contact hazards while operating a SCMI table saw which was equipped with a hood guard, but was not in use. HARTSON ENTERPRISES INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF OCCUPATIONAL SAFETY AND HEALTH STANDARD 29 CFR 1910.213(c)(1) OR ITS EQUIVALENT WHICH WAS CONTAINED IN OSHA INSPECTION 950439, CITATION 1, ITEM 2a, ISSUED FEBRUARY 12, 2014, WITH RESPECT TO THE WORKPLACE LOCATED AT 3340 S. ZUNI ST. BLDG. A, SHERIDAN, COLORADO 80110. THE CITATION BECAME FINAL ON MARCH 10, 2014. THE FINAL ABATEMENT DATE FOR THIS CITATION WAS APRIL 1, 2014 . |
|
Citation ID |
01001B |
Citaton Type |
Repeat |
Standard Cited |
19100213 C02 |
Issuance Date |
2018-04-09 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-05-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator: a) On or about February 22, 2018, and at times prior, the employer, Hartson Enterprises, Inc., did not ensure employees were protected from stuck-by hazards while operating and working in the vicinity of a SCMI table saw without a spreader device. HARTSON ENTERPRISES INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF OCCUPATIONAL SAFETY AND HEALTH STANDARD 29 CFR 1910.213(c)(2) OR ITS EQUIVALENT WHICH WAS CONTAINED IN OSHA INSPECTION 1008783, CITATION 1, ITEM 1a, ISSUED APRIL 29, 2015, WITH RESPECT TO THE WORKPLACE LOCATED AT 3340 S. ZUNI ST. BLDG. A, SHERIDAN, COLORADO 80110. THE CITATION BECAME FINAL ON MAY 26, 2015. THE FINAL ABATEMENT DATE FOR THIS CITATION WAS MAY 18, 2015. |
|
Citation ID |
01001C |
Citaton Type |
Repeat |
Standard Cited |
19100213 C03 |
Issuance Date |
2018-04-09 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-05-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: a) On or about February 22, 2018, and at times prior, the employer, Hartson Enterprises, Inc., did not ensure employees were protected from kickback (struck-by) hazards while operating and working in the vicinity of a SCMI table saw which was not equipped with non-kickback fingers. HARTSON ENTERPRISES INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF OCCUPATIONAL SAFETY AND HEALTH STANDARD 29 CFR 1910.213(c)(3) OR ITS EQUIVALENT WHICH WAS CONTAINED IN OSHA INSPECTION 1008783, CITATION 1, ITEM 1b, ISSUED APRIL 29, 2015, WITH RESPECT TO THE WORKPLACE LOCATED AT 3340 S. ZUNI ST. BLDG. A, SHERIDAN, COLORADO 80110. THE CITATION BECAME FINAL ON MAY 26, 2015. THE FINAL ABATEMENT DATE FOR THIS CITATION WAS MAY 18, 2015 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100036 D01 |
Issuance Date |
2018-04-09 |
Abatement Due Date |
2018-04-19 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-05-08 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge: a) On or about February 22, 2018, and at times prior, the employer, Hartson Enterprises, Inc., did not ensure the rear exit door was unlocked which would allow employee egress in case of fire or other emergency. |
|
|
341203511
|
0830600
|
2016-01-14
|
1825 W. CASPIAN PL., ENGLEWOOD, CO, 80110
|
|
Inspection Type |
FollowUp
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2016-01-14
|
Case Closed |
2022-04-27
|
Related Activity
Type |
Inspection |
Activity Nr |
1010109 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Willful |
Standard Cited |
19101052 D01 I |
Issuance Date |
2016-07-12 |
Abatement Due Date |
2016-08-12 |
Current Penalty |
22000.0 |
Initial Penalty |
22000.0 |
Contest Date |
2016-08-03 |
Final Order |
2017-06-19 |
Nr Instances |
3 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1052(d)(1)(i): Where methylene chloride is present in the workplace, the employer does not determine each employee's exposure: (a) The employer, Hartson Enterprises, Inc., is failing to determine each affected employees' exposure to methylene chloride. Affected employees are required to engage in processes involving exposure to Formica 170, a methylene chloride-containing adhesive. The following is a recently observed, specific example of the employer failing to comply with the cited standard: 1. On or about May 23, 2016, employees of Hartson Enterprises, Inc. were observed spraying Formica 170 onto laminate backing. Exposure determination for these affected employees had not been determined. |
|
Citation ID |
01001B |
Citaton Type |
Willful |
Standard Cited |
19101052 H01 |
Issuance Date |
2016-07-12 |
Abatement Due Date |
2016-08-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2016-08-03 |
Final Order |
2017-06-19 |
Nr Instances |
3 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1052(h)(1): Where needed to prevent methylene chloride induced skin or eye irritation, the employer does not provide clean protective clothing and equipment resistant to methylene chloride, at no cost to the employee, and/or does not ensure that each affected employee uses it: (a) The employer, Hartson Enterprises, Inc., is failing to ensure each affected employee exposed to chemical splashes of Formica 170, a methylene chloride-containing adhesive during container transfers or by direct exposure to the product during spraying operations, are protected by means of appropriate personal protective equipment. The following is a recently observed, specific example of the employer failing to comply with the cited standard: 1. On or about May 23, 2016, employees of Hartson Enterprises, Inc. were observed spraying Formica 170 onto laminate backing and in doing so, were coming into direct skin contact with the product. |
|
Citation ID |
01001C |
Citaton Type |
Willful |
Standard Cited |
19101052 L01 |
Issuance Date |
2016-07-12 |
Abatement Due Date |
2016-08-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2016-08-03 |
Final Order |
2017-06-19 |
Nr Instances |
3 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1052(l)(1): The employer does not provide information and training for each affected employee prior to or at the time of initial assignment to a job involving potential exposure to methylene chloride: (a) The employer, Hartson Enterprises, Inc., is failing to ensure that each affected employee, who is required to engage in processes involving exposure to Formica 170, a methylene chloride-containing adhesive, is provided effective information and training in regard to the hazards of methylene chloride exposure. The following is a recently observed, specific example of the employer failing to comply with the cited standard: 1. On or about May 23, 2016, employees of Hartson Enterprises, Inc. were observed spraying Formica 170 onto laminate backing and were not provided effective information and training in regard to the hazards of methylene chloride exposure. |
|
|
340087832
|
0830600
|
2014-11-18
|
3340 S ZUNI STREET, BUILDING A, SHERIDAN, CO, 80110
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-11-18
|
Case Closed |
2022-06-14
|
Related Activity
Type |
Inspection |
Activity Nr |
981784 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1010109 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Repeat |
Standard Cited |
19100213 C02 |
Issuance Date |
2015-04-29 |
Abatement Due Date |
2015-05-18 |
Current Penalty |
10000.0 |
Initial Penalty |
10000.0 |
Final Order |
2015-05-27 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator: a) On or about November 11, 2014, nd at times prior, employees were exposed to struck-by hazards while operating the SCMI saw with no spreaders in place. Hartson Enterprises was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1901.213(c)(2), which was contained in OSHA inspection number 950439, citation number 1, item number 2b, and was affirmed as a final order on March 11, 2014, with respect to a workplace located at 3340 S. Zuni St., Sheridan CO 80110. Hartson Enterprises was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1901.213(c)(2), which was contained in OSHA inspection number 981784, citation number 1, item number 1a, and was affirmed as a final order on October 8, 2014, with respect to a workplace located at 3340 S. Zuni St., Sheridan CO 80110. |
|
Citation ID |
01001B |
Citaton Type |
Repeat |
Standard Cited |
19100213 C03 |
Issuance Date |
2015-04-29 |
Abatement Due Date |
2015-05-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-05-27 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: a) On or about November 18, 2014, and at times prior, employees were exposes to struck-by injuries while operating the SCMI saw with no kickback fingers or dogs in place. Hartson Enterprises was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1901.213(c)(3), which was contained in OSHA inspection number 950439, citation number 1, item number 2c, and was affirmed as a final order on March 11, 2014, with respect to a workplace located at 3340 S. Zuni St., Sheridan CO 80110. Hartson Enterprises was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1901.213(c)(3), which was contained in OSHA inspection number 981784, citation number 1, item number 1b, and was affirmed as a final order on October 8, 2014, with respect to a workplace located at 3340 S. Zuni St., Sheridan CO 80110. |
|
|
340101096
|
0830600
|
2014-11-18
|
3340 S ZUNI STREET, BUILDING A, SHERIDAN, CO, 80110
|
|
Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2014-11-18
|
Related Activity
Type |
Referral |
Activity Nr |
987874 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1008783 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100133 A01 |
Issuance Date |
2015-04-29 |
Abatement Due Date |
2015-05-18 |
Current Penalty |
1200.0 |
Initial Penalty |
1200.0 |
Final Order |
2015-05-27 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.133(a)(1): Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment: a) On or about November 18, 2014, the employer, Hartson Enterprises, Inc., did not ensure employees, who were required to use pneumatic staple guns during manufacturing processes, were protected from eye injury by means of appropriate personal protective equipment. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19101052 D01 I |
Issuance Date |
2015-04-29 |
Abatement Due Date |
2015-06-16 |
Current Penalty |
2400.0 |
Initial Penalty |
2400.0 |
Final Order |
2015-05-27 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1052(d)(1)(i): Where methylene chloride was present in the workplace, the employer did not determine each employee's exposure: a) On or about November 18, 2014, the employer, Hartson Enterprises, Inc., did not determine employee exposure to methylene chloride during an adhesive spraying process. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19101052 H01 |
Issuance Date |
2015-04-29 |
Abatement Due Date |
2015-06-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-05-27 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1052(h)(1): Where needed to prevent methylene chloride induced skin or eye irritation, the employer did not provide clean protective clothing and equipment resistant to methylene chloride, at no cost to the employee, and/or did not ensure that each affected employee used it: a) On or about November 18, 2014, the employer, Hartson Enterprises, Inc., did not ensure employees exposed to chemical splashes of methylene chloride-containing adhesive during container transfers, were protected by means of appropriate personal protective equipment. |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19101052 L01 |
Issuance Date |
2015-04-29 |
Abatement Due Date |
2015-06-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-05-27 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1052(l)(1): The employer did not provide information and training for each affected employee prior to or at the time of initial assignment to a job involving potential exposure to methylene chloride: a) On or about November 18, 2014, the employer, Hartson Enterprises, Inc., did not ensure employees required to engage in processes involving exposure to a methylene chloride-containing adhesive, were provided effective information and training in regard to methylene chloride exposure. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100305 G01 IV B |
Issuance Date |
2015-04-29 |
Abatement Due Date |
2015-05-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-05-27 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) On or about November 18, 2014, the employer, Hartson Enterprises, Inc., did not ensure various pieces of powered equipment were powered by fixed wiring of the facility. Flexible cord sets were used as a substitute for the fixed wiring of the facility. |
|
Citation ID |
03001A |
Citaton Type |
Serious |
Standard Cited |
19101052 C02 |
Issuance Date |
2015-06-02 |
Abatement Due Date |
2015-06-26 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2015-07-31 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1052(c)(2): The employer did not ensure that no employee was exposed to an airborne concentration of methylene chloride in excess of 125 parts per million as determined over a sampling period of 15 minutes: a) On April 22, 2015, the employer, Hartson Enterprises, Inc., did not protect employees who were exposed to airborne concentrations of methylene chloride measuring approximately 225 parts per million and 205 parts per million, respectively, as determined by short term exposure limit (STEL) sampling during the Formica 170 adhesive spraying process. |
|
Citation ID |
03001B |
Citaton Type |
Serious |
Standard Cited |
19101052 E01 |
Issuance Date |
2015-06-02 |
Abatement Due Date |
2015-06-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-07-31 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1052(e)(1): The employer did not establish a regulated area wherever an employee's exposure to airborne concentrations of methylene chloride exceeded or could reasonably be expected to exceed either the 8-hour Time Weighted Average Permissible Exposure Limit or the Short Term Exposure Limit: a) On April 22, 2015, the employer, Hartson Enterprises, Inc., did not ensure a regulated area was established so as to address employee exposure to airborne concentrations of methylene chloride, which exceeded the Short Term Exposure Limit (STEL) during the Formica 170 adhesive spraying process. |
|
Citation ID |
03001C |
Citaton Type |
Serious |
Standard Cited |
19101052 F01 |
Issuance Date |
2015-06-02 |
Abatement Due Date |
2015-06-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-07-31 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1052(f)(1): The employer did not institute and maintain the effectiveness of engineering controls and work practices to reduce employee exposure to or below the permissible exposure limits and wherever the feasible engineering controls and work practices which can be instituted were not sufficient to reduce employee exposure to or below the 8-hour time weighted average permissible exposure limit or short term exposure limit, the employer did not use them to reduce employee exposure to the lowest levels achievable and did not supplement them by the use of respiratory protection that compiled with the requirements of 29 CFR 1910.1052(g): a) On April 22, 2015, the employer, Hartson Enterprises, Inc., did not ensure effective engineering controls were implemented and maintained so as to reduce or eliminate employee exposure to airborne concentrations of methylene chloride, which exceeded the Short Term Exposure Limit (STEL) during the Formica 170 adhesive spraying process. |
|
Citation ID |
03001D |
Citaton Type |
Serious |
Standard Cited |
19101052 G01 I |
Issuance Date |
2015-06-02 |
Abatement Due Date |
2015-06-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-07-31 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1052(g)(1)(i): Respirators were not used during periods when an employee's exposure to methylene chloride exceeds the 8-hour time weighted average permissible exposure limit or short term exposure limit: a) On April 22, 2015, the employer, Hartson Enterprises, Inc., did not ensure adequate respiratory protection was provided to employees so as to mitigate exposure to airborne concentrations of methylene chloride, which exceeded the Short Term Exposure Limit (STEL) during the Formica 170 adhesive spraying process. |
|
Citation ID |
03001E |
Citaton Type |
Serious |
Standard Cited |
19101052 J01 I |
Issuance Date |
2015-06-02 |
Abatement Due Date |
2015-06-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-07-31 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1052(j)(1)(i): The employer did not make medical surveillance available for employees who were or potentially were exposed to methylene chloride at or above the action level on 30 or more days per year, or above the 8-hour time weighted average permissible exposure limit or the short term exposure limit on 10 or more days per year: a) On April 22, 2015, the employer, Hartson Enterprises, Inc., did not ensure medical surveillance was provided to employees, who were exposed to airborne concentrations of methylene chloride which exceeded the short term exposure limit (STEL), while engaged in the Formica 170 adhesive spraying process. |
|
Citation ID |
03001F |
Citaton Type |
Serious |
Standard Cited |
19101052 L03 II |
Issuance Date |
2015-06-02 |
Abatement Due Date |
2015-06-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-07-31 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1052(l)(3)(ii): Where an employee(s) exposed to airborne concentrations of methylene chloride exceeded or can reasonably be expected to exceed the action level the employer did not inform each affected employee of the quantity, location, manner of use, release, storage, and/or specific operations that could result in exposure to methylene chloride particularly noting where exposures may be above the 8-hour time weighted average permissible exposure limit or the short term exposure limit: a) On April 22, 2015, the employer, Hartson Enterprises, Inc., did not ensure effective information and training regarding methylene chloride was provided to employees, who were exposed to airborne concentrations of methylene chloride which exceeded the short term exposure limit (STEL), while engaged in the Formica 170 adhesive spraying process. |
|
|
339817843
|
0830600
|
2014-06-11
|
3340 S ZUNI STREET, BUILDING A, SHERIDAN, CO, 80110
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-06-11
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2019-03-18
|
Related Activity
Type |
Inspection |
Activity Nr |
950439 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Repeat |
Standard Cited |
19100213 C02 |
Issuance Date |
2014-07-31 |
Abatement Due Date |
2014-08-19 |
Current Penalty |
4000.0 |
Initial Penalty |
4000.0 |
Final Order |
2014-10-08 |
Nr Instances |
2 |
Nr Exposed |
9 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator. a) On or about June 11, 2014, and at times prior, employees were exposed to stuck-by hazards (operators or employees in the vicinity of the saw), while operating table saws (Delta RT 31 and SCMI) without spreaders on the table saws. Hartson Enterprises, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.213(c)(2), which was contained in OSHA inspection number 950439, citation number 1, item number 2b and was affirmed as a final order on March 11, 2014, with respect to a workplace located at 3340 S. Zuni St, Sheridan, Co 80110. |
|
Citation ID |
01001B |
Citaton Type |
Repeat |
Standard Cited |
19100213 C03 |
Issuance Date |
2014-07-31 |
Abatement Due Date |
2014-08-19 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-10-08 |
Nr Instances |
2 |
Nr Exposed |
9 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator. a) On or about June 11, 2014, and at times prior, employees were exposed to stuck-by hazards (operators or employees in the vicinity of the saw), while operating table saws (Delta RT 31 and SCMI) without nonkickback fingers or dogs. Hartson Enterprises, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.213(c)(3), which was contained in OSHA inspection number 950439, citation number 1, item number 2c and was affirmed as a final order on March 11, 2014, with respect to a workplace located at 3340 S. Zuni St, Sheridan, Co 80110. |
|
Citation ID |
01001C |
Citaton Type |
Repeat |
Standard Cited |
19100213 H01 |
Issuance Date |
2014-07-31 |
Abatement Due Date |
2014-08-19 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-10-08 |
Nr Instances |
2 |
Nr Exposed |
9 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the material. a) On or about June 11, 2014, and at times prior, employees were exposed to an amputation hazard, while operating a hand crank radial saw( Evans E 24 Equipment-Evans Rotork) where the lower half of the blade was not guarded. Hartson Enterprises, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.213(h)(1), which was contained in OSHA inspection number 950439, citation number 1, item number 2d and was affirmed as a final order on March 11, 2014, with respect to a workplace located at 3340 S. Zuni St, Sheridan, Co 80110. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19100212 A01 |
Issuance Date |
2014-07-31 |
Abatement Due Date |
2014-08-19 |
Current Penalty |
80.0 |
Initial Penalty |
80.0 |
Final Order |
2014-10-08 |
Nr Instances |
2 |
Nr Exposed |
9 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. a) On or about June 11, 2014, and at times prior, employees were exposed to injuries from flying debris and particles while operating Delta drill presses that did not have guarding around the chuck and bit. Hartson Enterprises, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.212(a)(1), which was contained in OSHA inspection number 950439, citation number 2, item number 1 and was affirmed as a final order on March 11, 2014, with respect to a workplace located at 3340 S. Zuni St, Sheridan, Co 80110. |
|
Citation ID |
02002A |
Citaton Type |
Repeat |
Standard Cited |
19100305 G01 IV A |
Issuance Date |
2014-07-31 |
Abatement Due Date |
2014-08-19 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-10-08 |
Nr Instances |
2 |
Nr Exposed |
9 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure. a) On or about June 11, 2014 and at times prior, the employer exposed employees to fire hazards due to utilizing extension cords hanging throughout the ceiling as fixed wiring in the production work area. Extension cords were used to wire permanent fixtures involving receptacles mounted in the benches. Hartson Enterprises, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.305(g)(1)(iv)(A), which was contained in OSHA inspection number 950439, citation number 2, item number 2a and was affirmed as a final order on March 11, 2014, with respect to a workplace located at 3340 S. Zuni St, Sheridan, Co 80110. |
|
Citation ID |
02002B |
Citaton Type |
Repeat |
Standard Cited |
19100305 G02 III |
Issuance Date |
2014-07-31 |
Abatement Due Date |
2014-08-19 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-10-08 |
Nr Instances |
2 |
Nr Exposed |
9 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws. a) On or about June 11, 2014 and at times prior the employer did not ensure employees were protected from electrical shock in the wood shop due to not providing strain relief on hanging extension cords attached to the ceiling throughout the wood shop. Hartson Enterprises, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.305(g)(2)(iii), which was contained in OSHA inspection number 950439, citation number 2, item number 2b and was affirmed as a final order on March 11, 2014, with respect to a workplace located at 3340 S. Zuni St, Sheridan, Co 80110. |
|
|
339504391
|
0830600
|
2013-12-02
|
3340 S ZUNI STREET, BUILDING A, SHERIDAN, CO, 80110
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-12-02
|
Emphasis |
N: AMPUTATE, N: DUSTEXPL
|
Case Closed |
2021-06-10
|
Related Activity
Type |
Referral |
Activity Nr |
863157 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100022 A01 |
Issuance Date |
2014-02-12 |
Abatement Due Date |
2014-04-01 |
Current Penalty |
1200.0 |
Initial Penalty |
1200.0 |
Final Order |
2014-03-11 |
Nr Instances |
2 |
Nr Exposed |
9 |
Related Event Code (REC) |
Referral |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms were not kept clean and orderly and in a sanitary condition: a) On or about December 02, 2013, and at times prior, employees were exposed to fire, explosion, and slip/fall hazards because wood dust accumulation was present throughout the working facility and not adequately cleaned on a regular basis. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100213 C01 |
Issuance Date |
2014-02-12 |
Abatement Due Date |
2014-04-01 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Final Order |
2014-03-11 |
Nr Instances |
2 |
Nr Exposed |
9 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(c)(1): Circular hand-fed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut. a) On or about December 02, 2013, and at times prior, employees were exposed to amputation hazards, while operating two table saws (Delta RT 31 and SCMI) without guards. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100213 C02 |
Issuance Date |
2014-02-12 |
Abatement Due Date |
2014-04-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-03-11 |
Nr Instances |
2 |
Nr Exposed |
9 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator. a) On or about December 02, 2013, and at times prior, employees were exposed to stuck-by hazards (operators or employees in the vicinity of the saw), while operating table saws (Delta RT 31 and SCMI) without spreaders on the table saws. |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19100213 C03 |
Issuance Date |
2014-02-12 |
Abatement Due Date |
2014-04-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-03-11 |
Nr Instances |
2 |
Nr Exposed |
9 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(c)(3): Each hand-fed circular ripsaw shall be provided with nonkickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator. They shall be designed to provide adequate holding power for all the thicknesses of materials being cut. a) On or about December 02, 2013, and at times prior, employees were exposed to stuck-by hazards (operators or employees in the vicinity of the saw), while operating a table saws (Delta RT 31 and SCMI) without nonkickback fingers or dogs. |
|
Citation ID |
01002D |
Citaton Type |
Serious |
Standard Cited |
19100213 H01 |
Issuance Date |
2014-02-12 |
Abatement Due Date |
2014-04-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-03-11 |
Nr Instances |
2 |
Nr Exposed |
9 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the material. a) On or about December 02, 2013, and at times prior, employees were exposed to an amputation hazard, while operating a hand crank radial saw( Evans E 24 Equipment-Evans Rotork) where the lower half of the blade was not guarded. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100213 P04 |
Issuance Date |
2014-02-12 |
Abatement Due Date |
2014-04-01 |
Current Penalty |
1600.0 |
Initial Penalty |
1600.0 |
Final Order |
2014-03-11 |
Nr Instances |
2 |
Nr Exposed |
9 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(p)(4): Belt sanding machinery was not provided with a guard at each nip point where the sanding belt ran onto a pulley, to prevent the operator's hands or fingers from coming into contact with nip points. a) On or about December 02, 2013, and at times prior, employees were exposed to caught in hazards from nips points on a belt sander where no guard was installed covering the pulleys. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100305 B02 I |
Issuance Date |
2014-02-12 |
Current Penalty |
1020.0 |
Initial Penalty |
1020.0 |
Final Order |
2014-03-11 |
Nr Instances |
2 |
Nr Exposed |
9 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy. a) On or about December 02, 2013 and at times prior, the employer did not ensure employees were protected from electrical shock in the storage room/time clock area where two receptacles were not provided with a cover or faceplate. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100212 A01 |
Issuance Date |
2014-02-12 |
Abatement Due Date |
2014-04-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-03-11 |
Nr Instances |
2 |
Nr Exposed |
9 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. a) On or about December 02, 2013, and at times prior, employees were exposed to injuries from flying debris and particles while operating Delta drill presses that did not have guarding around the chuck and bit. |
|
Citation ID |
02002A |
Citaton Type |
Other |
Standard Cited |
19100305 G01 IV A |
Issuance Date |
2014-02-12 |
Abatement Due Date |
2014-04-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-03-11 |
Nr Instances |
2 |
Nr Exposed |
9 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure. a) On or about December 02, 2013 and at times prior, the employer exposed employees to fire hazards due to utilizing extension cords hanging throughout the ceiling as fixed wiring in the production work area. Extension cords were used to wire permanent fixtures involving receptacles mounted in the benches. |
|
Citation ID |
02002B |
Citaton Type |
Other |
Standard Cited |
19100305 G02 III |
Issuance Date |
2014-02-12 |
Abatement Due Date |
2014-04-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-03-11 |
Nr Instances |
2 |
Nr Exposed |
9 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws. a) On or about December 02, 2013 and at times prior the employer did not ensure employees were protected from electrical shock in the wood shop due to not providing strain relief on electrical equipment and electrical cords as follows: 1) Hanging extension cords attached to the ceiling throughout the wood shop were not provided with strain relief to prevent pull from being directly transmitted to joints or terminal screws. 2) An electrical cord connected to the disk sander motor had the jacket pulled back and frayed. |
|
|
110540739
|
0830600
|
1999-08-10
|
3340 S. ZUNI ST., UNIT A, SHERIDAN, CO, 80110
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
1999-08-10
|
Case Closed |
1999-12-17
|
Related Activity
Type |
Complaint |
Activity Nr |
202730198 |
Safety |
Yes |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100022 D01 |
Issuance Date |
1999-11-19 |
Abatement Due Date |
1999-11-23 |
Initial Penalty |
225.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100023 C01 |
Issuance Date |
1999-11-19 |
Abatement Due Date |
1999-11-23 |
Current Penalty |
100.0 |
Initial Penalty |
300.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
02 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100213 C01 |
Issuance Date |
1999-11-19 |
Abatement Due Date |
1999-11-23 |
Current Penalty |
100.0 |
Initial Penalty |
300.0 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
02 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100242 B |
Issuance Date |
1999-11-19 |
Abatement Due Date |
1999-11-23 |
Current Penalty |
100.0 |
Initial Penalty |
300.0 |
Nr Instances |
5 |
Nr Exposed |
6 |
Gravity |
02 |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100303 B01 |
Issuance Date |
1999-11-19 |
Abatement Due Date |
1999-11-23 |
Current Penalty |
100.0 |
Initial Penalty |
300.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
02 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19101200 F05 I |
Issuance Date |
1999-11-19 |
Abatement Due Date |
1999-11-23 |
Nr Instances |
3 |
Nr Exposed |
6 |
Related Event Code (REC) |
Complaint |
Gravity |
01 |
|
|