Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2022-12-07
|
Case Closed |
2023-05-05
|
Related Activity
Type |
Complaint |
Activity Nr |
1972849 |
Safety |
Yes |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2023-04-20 |
Abatement Due Date |
2023-05-25 |
Current Penalty |
4687.8 |
Initial Penalty |
7813.0 |
Final Order |
2023-05-05 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Mark Williams Enterprises, Inc. at 765 South Pierce Avenue in Louisville, CO: On or about December 7, 2022, and at times prior, employees were exposed to crushing and amputation hazards when the chain and sprocket was not guarded on the rotating welder in the drive shaft department. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100253 B04 III |
Issuance Date |
2023-04-20 |
Abatement Due Date |
2023-05-25 |
Current Penalty |
3750.0 |
Initial Penalty |
6250.0 |
Final Order |
2023-05-05 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: (a) Mark Williams Enterprises, Inc. at 765 South Pierce Avenue in Louisville, CO: On or about December 7, 2022, and at times prior, employees were exposed to fire and explosion hazards when an oxygen cylinder was stored next to an acetylene cylinder in the fabrication department. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19101200 F06 |
Issuance Date |
2023-04-20 |
Abatement Due Date |
2023-05-25 |
Current Penalty |
5625.6 |
Initial Penalty |
9376.0 |
Final Order |
2023-05-05 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(6): The employer used written materials, such as signs, placards, process sheets, or batch tickets in lieu of affixing labels to individual stationary process containers that failed to identify the container(s) to which they were applicable and did not convey the information required by 29 CFR 1910.1200(f)(5): (a) Mark Williams Enterprises, Inc. at 765 South Pierce Avenue in Louisville, CO: On or about December 7, 2022, and at times prior, employees were exposed to corrosive and carcinogenic chemicals in the heat treat area, but containers were not labeled with the chemical identity nor general hazards. Hazardous chemicals included: ? Alchrome 2 ? E-Kleen SR 148-E ? Insta-Blak 333 |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19101200 H03 |
Issuance Date |
2023-04-20 |
Abatement Due Date |
2023-05-25 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-05-05 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(3): The employee training did not include the requirements of 29 CFR 1910.1200(h)(3)(i) through (h)(3)(iv): (a) Mark Williams Enterprises, Inc. at 765 South Pierce Avenue in Louisville, CO: On or about December 7, 2022, and at times prior, employees were exposed to corrosive and carcinogenic chemicals in the heat treat area, but the employer did not ensure they were trained on the specific hazards of the chemicals in their work area. Hazardous chemicals included: ? Alchrome 2 ? E-Kleen SR 148-E ? Insta-Blak 333 |
|
|