339551012
|
0830600
|
2014-01-08
|
11001 W I-70 FRONTAGE ROAD N., WHEAT RIDGE, CO, 80033
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2014-01-17
|
Emphasis |
L: AUTOSERV, N: ISOCYAN8, P: ISOCYAN8
|
Case Closed |
2014-03-18
|
Related Activity
Type |
Referral |
Activity Nr |
867289 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19101052 D02 |
Issuance Date |
2014-02-14 |
Current Penalty |
1090.0 |
Initial Penalty |
2168.0 |
Final Order |
2014-03-03 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1052(d)(2): The employer did not perform initial monitoring to determine each employee's exposure to methylene chloride: a) On or about January 8, 2014, and at times prior, employees were exposed to unknown concentrations of methylene chloride because the employer failed to conduct an initial exposure assessment for employees that used Kleen Strip Aircraft Remover, which contained up to 90% methylene chloride, to remove paint from auto body parts. |
|
Citation ID |
02001A |
Citaton Type |
Other |
Standard Cited |
19100134 E01 |
Issuance Date |
2014-02-14 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-03-03 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) On or about January 8, 2014, and at times prior, employees wore half-face elastomeric respirators without first being medically evaluated to ensure that they were physiologically fit to wear the respirator. |
|
Citation ID |
02001B |
Citaton Type |
Other |
Standard Cited |
19100134 F02 |
Issuance Date |
2014-02-14 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-03-03 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(f)(2): The employer shall ensure that an employee using a tight-fitting facepiece respirator is fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter: a) On or about January 8, 2014, and at times prior, employees were exposed to methylene chloride, isocyanates, xylene and other hazardous chemicals while they performed spray finishing work using half-face respirators which had not been fit tested. |
|
|
339536682
|
0830600
|
2014-01-03
|
11001 W I-70 FRONTAGE ROAD N., WHEAT RIDGE, CO, 80033
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2014-01-03
|
Emphasis |
L: AUTOSERV, P: AUTOSERV
|
Case Closed |
2014-03-18
|
Related Activity
Type |
Referral |
Activity Nr |
867289 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19101200 F05 |
Issuance Date |
2014-02-07 |
Abatement Due Date |
2014-03-06 |
Current Penalty |
1060.0 |
Initial Penalty |
2100.0 |
Final Order |
2014-03-03 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(5): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged, or marked with the identity and appropriate hazard warnings regarding the chemicals contained therein: (a) On or about Janauray 3, 2013, the employer exposed employees in the automotive area to chemical hazards due to missing or no labels on plastic containers containing chemicals used for automobile repair. Abatement Note: Abatement certification and documentation is not required for this item (see enclosed "Certification of Corrective Action Worksheet"). |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100334 A02 I |
Issuance Date |
2014-02-07 |
Abatement Due Date |
2014-03-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-03-03 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): (a) On or about January 3, 2014, the employer did not ensure employees were protected from a electrical shock hazards in the Main Bay, due to a damaged electrical cord on a portable automotive light. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet"). |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100305 E01 |
Issuance Date |
2014-02-07 |
Abatement Due Date |
2014-03-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-03-03 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures were not weatherproof in wet locations: (a) On or about January 3, 2014, the employer exposed employees to electrical hazards in the Automotive Service Department and Body Shop Detailing area's, due to missing water proof electrical receptacle covers. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet"). |
|
|